Maintenance Skills of Electron Beam Evaporator Coating Machine
Maintenance Skills of Electron Beam Evaporator Coating Machine
During the use of the electronic evaporation beam coating machine, there may be large or small faults due to the characteristics of its own equipment. The faults are mostly caused by short circuits and residues of coating materials.
1. There is a burnt smell in the vacuum cavity
When the equipment is in use, there is a burnt smell from the vacuum chamber. The first thing to judge is whether the parts are damaged or burned. If the part has no abnormality or damage after the inspection, then the staff needs to carry out a step-by-step inspection of the equipment. In the process of maintenance, the cavity needs to be detected by the method of exclusion. The electronic evaporation source is the main structure of the entire system, and it is also the location that needs to be detected most when troubleshooting.
2. The electron gun does not work properly
Since the electron beam is generated by the electron gun, if the electron gun cannot work normally, it will affect the normal operation of the whole equipment. The first thing to check is whether the connection part of the high-voltage cable is normal. If it is normal, you need to check whether the surrounding environment is relatively humid. The humid environment may cause a short circuit of the circuit and equipment failure.
3. The electron beam cannot be loaded normally
This kind of fault may be caused by carbon deposition or a short circuit in the electrode or the voltage regulator. It is normal at low current, but when the current rises to a certain value, it will break down, and the circuit breaker will trip. It is best to use a megohmmeter to detect the phenomenon.